| General Information |
 |
|
 |
| Stage |
 |
| A 1:25 ground plan of the Opera House is available on request. |
| General Stage Information |
 |
| Stage Height |
1300mm |
| Stage Rake |
None |
| Proscenium Width |
8450mm |
| Proscenium Height |
5500mm |
| Stage Depth |
8300mm to setting line 9100mm front of forestage |
| Stage extension (losing 48 seats) |
13100mm |
| Height to Grid |
14000mm |
| Scenery Flying Height |
12500mm |
| Height to Fly Floor |
5750mm |
| Flying width |
11000mm |
| Wing space |
| – Stage Left |
4700mm |
| - Stage right |
3400mm |
| Loading access doors |
4500mm by 2200mm |
| Dock |
5000mm by 3000mm to stage |
|
|
 |
| General Stage Equipment |
 |
| The Venue has a selection of: - |
 |
| Stage braces/French braces of varying sizes |
| 20 Stage Weights |
| Various lengths of conduit |
| 4 x hard black masking legs |
|
|
 |
| Rostra |
 |
| 4 x 8by4 steel deck tops with varied sized legs (please check in advance) |
|
|
 |
| Flying |
 |
| Flying Lines Counterweight |
33 Sets |
| Weight Capacity Per Cradle |
400Kg (873lb) |
| Flying Bar Lengths |
11m (steel ‘H’ bars) |
|
|
| |
| Masking |
 |
| The venue has: - |
 |
| One set of black masking, comprising of: - |
 |
| 2 x set of full black tabs 18 ft high |
| 4 x Black borders |
| 8 x 3 metre wide black legs |
| 1 x Black Gauze |
| 1 x White Cyc |
| 1 x Set of Dark Blue with gold trimming house tabs |
|
|
 |
| The venue also has three tab tracks. (2 rope pull and 1 manual swipe) |
| The Jersey Opera House is a traditional Edwardian horseshoe style auditorium with a curved proscenium arch and seating 620 people on three levels; Stalls, Dress Circle and Upper Circle. |
| Public access is via the Box Office entrance in Gloucester Street while stage door and Scene Dock door are situated in Seaton Place. |
| SAFETY CURTAIN MUST BE PRESENTED TO THE AUDIENCE FOR EACH PERFORMANCE |
| Flying System. All Bars are on a single purchase counterweight |
 |
| |
Stage front
|
House tabs |
| Edge of stage |
0m |
- |
| Safety Curtain |
800mm |
- |
| 1(Permanent house tabs) |
1450mm |
0mm |
| 2 |
1800mm |
350mm |
| 3 |
2000mm |
550mm |
| 4 |
2200mm |
750mm |
| 5 |
2400mm |
950mm |
| 6 |
2600mm |
1150mm |
| 7 |
2800mm |
1350mm |
| 8 |
3000mm |
1550mm |
| 9 |
3200mm |
1750mm |
| 10 |
3400mm |
1950mm |
| 11 |
3600mm |
2150mm |
| 12 |
|
|
| 13 |
|
|
| 14 |
4200mm |
2750mm |
| 15 |
4400mm |
2950mm |
| 16 |
4600mm |
3150mm |
| 17 |
4800mm |
3350mm |
| 18 |
5000mm |
3550mm |
| 19 |
5200mm |
3750mm |
| 20 |
5400mm |
3950mm |
| 21 |
5600mm |
4150mm |
| 22 |
5800mm |
4350mm |
| 23 |
6000mm |
4550mm |
| 24 |
6200mm |
4750mm |
| 25 |
6400mm |
4950mm |
| 26 |
6600mm |
5150mm |
| 27 |
6800mm |
5350mm |
| 28 |
7000mm |
5550mm |
| 29 |
|
|
| 30 |
|
|
| 31 |
7600mm |
6150mm |
| 32 |
7800mm |
6350mm |
| 33 |
8000mm |
6550mm |
| 34 |
8200mm |
6750mm |
| 35 |
8400mm |
6950mm |
| 36 |
8600mm |
7150mm |
| 37 |
8800mm |
7350mm |
| Bars 12,13 29 & 30 are not installed |
|
|
 |
| Visiting Lighting Supply |
 |
| The visiting lighting power is situated down stage Left. The supply is 200 amps, 3 phases.
The distribution outlets are as follows: |
| Type |
Phase |
Number |
| 200amp Power locks |
3 |
1 set |
|
|
 |
| DUE TO LIMITED POWER SUPPLY USING TOURING POWER IS TAKEN FROM ON STAGE IN-HOUSE DIMMER POWER. ONLY IN-HOUSE FRONT OF HOUSE IS ISOLATED. |
| Visiting Sound Supply |
 |
| The visiting sound supply is situated under stage right. The distribution outlets are as follows: - |
| Type |
Phase |
Number |
| 32 amp Ceeform |
1 |
1 |
| 63amp Ceeform |
1 |
1 |
|
|
 |
| We have stage left and right clean 2x 13amp and 1 x 16amp power |
| There are at least 8 x 13amp power outlets each side of stage |
| Luminaries List |
 |
| Profiles |
| Type |
No. |
| Strand SL 15/33 (600w) |
18 |
| Strand SL 23/50 (600w) |
24 |
| Strand SL 10Degree fixed (600w) |
5 |
| ETC source 4 19degree (575w) |
2 |
|
|
 |
| 14 Strand SL 23/50 are permanently rigged FOH |
 |
| Fresnels |
| Type |
No. |
| Strand Quartet PC’s (650w) |
10 |
| Strand Quartet F’s (650w) |
20 |
| Strand Cantata PC’s (1200w) |
10 |
| Strand Cantata F’s (1200w) |
20 |
| Strand Alto (2500w) |
6 |
|
|
 |
| Floods and Par Cans |
| Type |
No. |
| ETC source 4 Par (750w) |
20 |
| Strand Coda floods (500w) |
12 |
| Strand iris3 cyc floods (1250w) |
4 |
|
|
| We have 20 of each lens type for the ETC pars (CP60, 61, 62, 95). |
| 8 x Mac 250’s, 18 Chroma-Q scroller units and PSU/splitter box, 1 x 20” Mirror ball, 1 x Jem ZR24/7 Hazer, 2 x Data Smoke factory, 1 x Jem Glaciator heavy smoke, |
| ALL CAN BE HIRED AT A FEE |
| Follow Spots |
| The venue has two Selecon Performance F.S follow spots situated at the back of the upper circle in a ventilated room. |
| Front of House Lighting Positions |
 |
| Circle front (fixed FOH position) |
12400mm |
| Upper circle |
13700mm |
| Auditorium Perches left and right |
15000mm |
| Boxes Left and Right |
5400mm |
| Dome position |
14200mm |
| Rear aud roof positions |
17500mm |
|
|
 |
| All positions done to stage front center line |
| On Stage Lighting Positions |
 |
The venue has four internally wired bars: -
2 x 18 ways
2 x 12 ways
The venue also has: -
4 x Ladders (fixed on runners 2 each side of stage)
4 x Boom Bases
|
| Also various lengths of scaffold for booms |
| PLEASE NOTE THAT DUE TO THE NATURE OF RESTORATION WORK NO ADDITIONAL RIGGING OF LIGHTING OR SOUND WILL BE ALLOWED IN THE AUDITORIUM. |
| Control |
 |
| The Lighting control is provided by a Strand 520i. Back up desk is 510i. |
| Dimming |
 |
| Strand LD90, 136 x 2.5k dimmers and 4 x 5k dimmers plus dimming for house lights, provides dimming
The dimmers all have hard-wired outlets and their locations are as follows. |
| Dimmers 1 to 6 |
Aud Left box |
| Dimmers 7 to 12 |
Aud right box |
| Dimmers 13 to 24 |
ADV bars |
| Dimmers 25 to 27 |
Dress circle bar |
| Dimmers 28 to 41 |
Upper circle bar |
| Dimmer 42 to 47 |
Aud Left Perch |
| Dimmer 48 to 50 |
Dome |
| Dimmer 51 to 56 |
Aud Right Perch |
| Dimmers 57 to 116 |
Stage overhead |
| Dimmers 117 to 128 |
Stage L & R ladders |
| Dimmers 129 to 132 |
Stage right floor |
| Dimmers 133 to 136 |
Stage Left floor |
|
|
 |
| Communications |
 |
| The Opera has 10 Tech Pro Belt packs and head sets available.
There are various comms points around the venue in all the usual places.
|
| Cue Lights |
 |
| The Opera House has a 12-way Q light system, which is patchable to various points around the venue. |
| Video |
 |
| There are a number of video tie lines around the building, there is a camera FOH that feeds the patch bay. This system can be extended to anywhere in the building. |
| Sound Equipment |
 |
| PA System |
| There are several sound distribution boxes around the auditorium and stage area, each has tie lines, speacon outlets, com’s and cue light points, AV BNC points and some have DMX outlets. |
PA Equipment |
 |
| Mixer |
Soundcraft – K2 - 24 mono channels 4 stereo, 8 aux, 4-matrix output |
| Mixer Other |
Soundcraft spirit folio 12 channel |
| Outboard Equipment |
Yamaha REV500 digital reverb unit
TC M3000 digital reverb/effect unit
2 x XTA GQ600 31 band graphics
2 x XTA DP224 loudspeaker controllers
4 x Behringer Composer Pro 2
4 x Behringer 3102 31 band graphics
Denon DNT620 CD/cassette player
2 x Sony MDS E11 Mini disc player |
|
|
 |
| Amplifiers Main PA |
| 14 x D&B E-PAC dedicated amplifiers |
| Amplifiers (Monitors) |
| 1 x RCF 1200 2 channel |
| PA Speakers F.O.H. |
 |
8 x D&B C690 Mid/High cabinets
2 x D&B E18 Sub cabinets
6 x D&B E3 loudspeakers
4 x Flying frames for above |
| Monitor Speakers |
 |
| 2 x Community 15” driver wedges |
| Microphones |
 |
6 x Shure SM58
5 X Shure SM57
2 x Audio Technica AT4053
2 x PCC160
1 x Audio Technica AT4033a/SC
1 x Shure SH55 (50’s period look) with SM58 head
2 x BSS AR133 DI boxes
2 x EMO DI boxes
13 Beyer Dynamic Microphone stands
14 x Sennheiser Evolution 500 Series radio microphone receivers, with 12 Belt packs and 4 Hand held transmitters.
THESE CAN BE HIRED AT A FEE |
| Visiting Mixer Position |
 |
| Rear Stalls |
|
| Requiring at least |
50mtrs of multicore |
|
|
 |
| Health and Safety at Work Act |
 |
| Would all incoming companies ensure that their employees or contractors work with in the Health and Safety at Work Act. |
| LOLER |
 |
| The Jersey Opera House is striving to meet the requirements of The Lifting Operations and Lifting Equipment Regulations 1998.
Would all incoming companies ensure that they have in their possession the correct documentation for any lifting equipment that is being brought in. Lifting equipment not having the correct documentation and test certificates will not be permitted to enter the building. |
| Portable Appliance Testing |
 |
| Would all in coming companies ensure that all electrical equipment to be brought into the Opera house has been tested within the last twelve months, and ensure the equipment is marked and records are carried for inspection. Electrical equipment deemed to be in an unsafe condition would not be permitted to enter the building. But for a small fee we can PAT test all items. |
| Fire Regulations |
 |
| The States of Jersey Fire Regulations require a Public Exemption Certificate for all performances, which use pyrotechnics, smoke machines and the smoking of cigarettes. If your performance contains such effects please contact the Technical manager as soon as possible. Applications received any later than three weeks before first performance will not be granted. All areas backstage are designated No Smoking Areas. |
| Please note: From 2007 Jersey will introduce non-smoking law in all enclosed work places. |
| Pyrotechnics |
 |
| If you are bringing pyrotechnics into Jersey an Import Licence and Port d’arm certificate will be required. This also applies to fire arms unless they are soft metal blank-firers. These certificates need to be obtained in Jersey and we will therefore require full details of any such items you intend to bring. It is worth noting that there is a very good local supplier for most pyrotechnics. Applications received any later than three weeks before first performance will not be granted. |
| Vehicle Size (touring companies) |
 |
| We may need to organize a police escort from the harbour to the theatre depending on the size of your vehicle. Please therefore ensure that all details of the vehicles you tour are provided to us as soon as possible. |
| Sound Distribution boxes |
 |
| Box No. |
Location
|
Detail |
| B2 |
Follow Spot Box |
T1 & 2; 1 x Comms; Q2. |
| B3 |
U/Circle S/L |
T3 & 4; 1 x Comms; S1 & 2. |
| B4 |
U/Circle S/R |
T5 & 6; 1 x Comms; S3 & 4 |
| B5 |
Flys S/L |
T7 & 8; 1 x Comms; Q3; S5 & 6; AV1 & 2. |
| B6 |
Flys S/R |
T9 & 10; 1 x Comms; Q4; S7 & 8; AV1 & 2. |
| B7 |
Adv. Bar Roof Void |
T11 & 12; 1 x Comms; AV1 & 2; 1 x DMX; S9 - 14. |
| B8 |
D/Circle Front |
T13 & 14; 1 x Comms; AV1 & 2; Rel/Mic; 1 x DMX. |
| B9 |
D/Circle S/L Box |
T15 & 16; 1 x Comms; S16 & 16; 1 x DMX. |
| B10 |
D/Circle S/R Box |
T17 & 18; 1 x Comms; S17 & 18; 1 x DMX |
| B15 |
DSR |
T29 - 36; S19 & 20; 1 x Comms; Q6; AV1 & 2; 1 x
DMX; L1 - 8; Prompt desk; 3 x 13amp;
1 x 16amp. |
| B16 |
USR |
T37 - 40; 1 x Comms; Q7; S21 & 22; AV! & 2. |
| B17 |
USL |
41 - 44; 1 x Comms; Q8; S23 & 24; AV1 & 2. |
| B18 |
DSL |
T45 - 52; S25 & 26; 1 x Comms; Q9; AV1 & 2; 1 x
DMX; 1 x Rigger; L1 - 8; Prompt desk; 3 x 13amp;
1 x 16amp. |
| B19 |
Pros Wall S/L |
S27 - 29. |
| B20 |
| | |