space
Jersey Opera House
Increase Text Size
search
Font Decrease Font Increase
space
Home What's On Box Office Contact Information History Corporate Events Links Mailing List
space
space
space
Search by shows
space
Go
space
Example:
musical, comedy, drama, etc.
space
space
space
space
space
space
Full Theatre Technical Spec
space
 
INFORMATION - Full Theatre Technical Spec
General Information
space
Jersey Opera house
space
space
Stage
space
A 1:25 ground plan of the Opera House is available on request.
General Stage Information
space
Stage Height 1300mm
Stage Rake None
Proscenium Width 8450mm
Proscenium Height 5500mm
Stage Depth 8300mm to setting line 9100mm front of forestage
Stage extension (losing 48 seats) 13100mm
Height to Grid 14000mm
Scenery Flying Height 12500mm
Height to Fly Floor 5750mm
Flying width 11000mm
Wing space
– Stage Left 4700mm
- Stage right 3400mm
Loading access doors 4500mm by 2200mm
Dock 5000mm by 3000mm to stage
space
General Stage Equipment
space
The Venue has a selection of: -
space
Stage braces/French braces of varying sizes
20 Stage Weights
Various lengths of conduit
4 x hard black masking legs
space
Rostra
space
4 x 8by4 steel deck tops with varied sized legs (please check in advance)
space
Flying
space
Flying Lines Counterweight 33 Sets
Weight Capacity Per Cradle 400Kg (873lb)
Flying Bar Lengths 11m (steel ‘H’ bars)
 
Masking
space
The venue has: -
space
One set of black masking, comprising of: -
space
2 x set of full black tabs 18 ft high
4 x Black borders
8 x 3 metre wide black legs
1 x Black Gauze
1 x White Cyc
1 x Set of Dark Blue with gold trimming house tabs
space
The venue also has three tab tracks. (2 rope pull and 1 manual swipe)
The Jersey Opera House is a traditional Edwardian horseshoe style auditorium with a curved proscenium arch and seating 620 people on three levels; Stalls, Dress Circle and Upper Circle.
Public access is via the Box Office entrance in Gloucester Street while stage door and Scene Dock door are situated in Seaton Place.
SAFETY CURTAIN MUST BE PRESENTED TO THE AUDIENCE FOR EACH PERFORMANCE
Flying System. All Bars are on a single purchase counterweight
space
  Stage front
House tabs
Edge of stage 0m -
Safety Curtain 800mm -
1(Permanent house tabs) 1450mm 0mm
2 1800mm 350mm
3 2000mm 550mm
4 2200mm 750mm
5 2400mm 950mm
6 2600mm 1150mm
7 2800mm 1350mm
8 3000mm 1550mm
9 3200mm 1750mm
10 3400mm 1950mm
11 3600mm 2150mm
12    
13    
14 4200mm 2750mm
15 4400mm 2950mm
16 4600mm 3150mm
17 4800mm 3350mm
18 5000mm 3550mm
19 5200mm 3750mm
20 5400mm 3950mm
21 5600mm 4150mm
22 5800mm 4350mm
23 6000mm 4550mm
24 6200mm 4750mm
25 6400mm 4950mm
26 6600mm 5150mm
27 6800mm 5350mm
28 7000mm 5550mm
29    
30    
31 7600mm 6150mm
32 7800mm 6350mm
33 8000mm 6550mm
34 8200mm 6750mm
35 8400mm 6950mm
36 8600mm 7150mm
37 8800mm 7350mm
Bars 12,13 29 & 30 are not installed
space
Visiting Lighting Supply
space
The visiting lighting power is situated down stage Left. The supply is 200 amps, 3 phases. The distribution outlets are as follows:
Type Phase Number
200amp Power locks 3 1 set
space
DUE TO LIMITED POWER SUPPLY USING TOURING POWER IS TAKEN FROM ON STAGE IN-HOUSE DIMMER POWER. ONLY IN-HOUSE FRONT OF HOUSE IS ISOLATED.
Visiting Sound Supply
space
The visiting sound supply is situated under stage right. The distribution outlets are as follows: -
Type Phase Number
32 amp Ceeform 1 1
63amp Ceeform 1 1
space
We have stage left and right clean 2x 13amp and 1 x 16amp power
There are at least 8 x 13amp power outlets each side of stage
Luminaries List
space
Profiles
Type No.
Strand SL 15/33 (600w) 18
Strand SL 23/50 (600w) 24
Strand SL 10Degree fixed (600w) 5
ETC source 4 19degree (575w) 2
space
14 Strand SL 23/50 are permanently rigged FOH
space
Fresnels
Type No.
Strand Quartet PC’s (650w) 10
Strand Quartet F’s (650w) 20
Strand Cantata PC’s (1200w) 10
Strand Cantata F’s (1200w) 20
Strand Alto (2500w) 6
space
Floods and Par Cans
Type No.
ETC source 4 Par (750w) 20
Strand Coda floods (500w) 12
Strand iris3 cyc floods (1250w) 4
We have 20 of each lens type for the ETC pars (CP60, 61, 62, 95).
8 x Mac 250’s, 18 Chroma-Q scroller units and PSU/splitter box, 1 x 20” Mirror ball, 1 x Jem ZR24/7 Hazer, 2 x Data Smoke factory, 1 x Jem Glaciator heavy smoke,
ALL CAN BE HIRED AT A FEE
Follow Spots
The venue has two Selecon Performance F.S follow spots situated at the back of the upper circle in a ventilated room.
Front of House Lighting Positions
space
Circle front (fixed FOH position) 12400mm
Upper circle 13700mm
Auditorium Perches left and right 15000mm
Boxes Left and Right 5400mm
Dome position 14200mm
Rear aud roof positions 17500mm
space
All positions done to stage front center line
On Stage Lighting Positions
space
The venue has four internally wired bars: -
2 x 18 ways
2 x 12 ways

The venue also has: -
4 x Ladders (fixed on runners 2 each side of stage)
4 x Boom Bases

Also various lengths of scaffold for booms
PLEASE NOTE THAT DUE TO THE NATURE OF RESTORATION WORK NO ADDITIONAL RIGGING OF LIGHTING OR SOUND WILL BE ALLOWED IN THE AUDITORIUM.
Control
space
The Lighting control is provided by a Strand 520i. Back up desk is 510i.
Dimming
space
Strand LD90, 136 x 2.5k dimmers and 4 x 5k dimmers plus dimming for house lights, provides dimming

The dimmers all have hard-wired outlets and their locations are as follows.

Dimmers 1 to 6 Aud Left box
Dimmers 7 to 12 Aud right box
Dimmers 13 to 24 ADV bars
Dimmers 25 to 27 Dress circle bar
Dimmers 28 to 41 Upper circle bar
Dimmer 42 to 47 Aud Left Perch
Dimmer 48 to 50 Dome
Dimmer 51 to 56 Aud Right Perch
Dimmers 57 to 116 Stage overhead
Dimmers 117 to 128 Stage L & R ladders
Dimmers 129 to 132 Stage right floor
Dimmers 133 to 136 Stage Left floor
space
Communications
space
The Opera has 10 Tech Pro Belt packs and head sets available.

There are various comms points around the venue in all the usual places.

Cue Lights
space
The Opera House has a 12-way Q light system, which is patchable to various points around the venue.
Video
space
There are a number of video tie lines around the building, there is a camera FOH that feeds the patch bay. This system can be extended to anywhere in the building.
Sound Equipment
space
PA System
There are several sound distribution boxes around the auditorium and stage area, each has tie lines, speacon outlets, com’s and cue light points, AV BNC points and some have DMX outlets.

PA Equipment

space
Mixer Soundcraft – K2 - 24 mono channels 4 stereo, 8 aux, 4-matrix output
Mixer Other Soundcraft spirit folio 12 channel
Outboard Equipment Yamaha REV500 digital reverb unit
TC M3000 digital reverb/effect unit

2 x XTA GQ600 31 band graphics
2 x XTA DP224 loudspeaker controllers

4 x Behringer Composer Pro 2
4 x Behringer 3102 31 band graphics

Denon DNT620 CD/cassette player
2 x Sony MDS E11 Mini disc player

space
Amplifiers Main PA
14 x D&B E-PAC dedicated amplifiers
Amplifiers (Monitors)
1 x RCF 1200 2 channel
PA Speakers F.O.H.
space
space8 x D&B C690 Mid/High cabinets
2 x D&B E18 Sub cabinets
6 x D&B E3 loudspeakers
4 x Flying frames for above
Monitor Speakers
space
2 x Community 15” driver wedges
Microphones
space
6 x Shure SM58
5 X Shure SM57
2 x Audio Technica AT4053
2 x PCC160
1 x Audio Technica AT4033a/SC
1 x Shure SH55 (50’s period look) with SM58 head
2 x BSS AR133 DI boxes
2 x EMO DI boxes
13 Beyer Dynamic Microphone stands
14 x Sennheiser Evolution 500 Series radio microphone receivers, with 12 Belt packs and 4 Hand held transmitters.
THESE CAN BE HIRED AT A FEE
Visiting Mixer Position
space
Rear Stalls  
Requiring at least 50mtrs of multicore
space
Health and Safety at Work Act
space
Would all incoming companies ensure that their employees or contractors work with in the Health and Safety at Work Act.
LOLER
space
The Jersey Opera House is striving to meet the requirements of The Lifting Operations and Lifting Equipment Regulations 1998.

Would all incoming companies ensure that they have in their possession the correct documentation for any lifting equipment that is being brought in. Lifting equipment not having the correct documentation and test certificates will not be permitted to enter the building.

Portable Appliance Testing
space
Would all in coming companies ensure that all electrical equipment to be brought into the Opera house has been tested within the last twelve months, and ensure the equipment is marked and records are carried for inspection. Electrical equipment deemed to be in an unsafe condition would not be permitted to enter the building. But for a small fee we can PAT test all items.
Fire Regulations
space
The States of Jersey Fire Regulations require a Public Exemption Certificate for all performances, which use pyrotechnics, smoke machines and the smoking of cigarettes. If your performance contains such effects please contact the Technical manager as soon as possible. Applications received any later than three weeks before first performance will not be granted. All areas backstage are designated No Smoking Areas.
Please note: From 2007 Jersey will introduce non-smoking law in all enclosed work places.
Pyrotechnics
space
If you are bringing pyrotechnics into Jersey an Import Licence and Port d’arm certificate will be required. This also applies to fire arms unless they are soft metal blank-firers. These certificates need to be obtained in Jersey and we will therefore require full details of any such items you intend to bring. It is worth noting that there is a very good local supplier for most pyrotechnics. Applications received any later than three weeks before first performance will not be granted.
Vehicle Size (touring companies)
space
We may need to organize a police escort from the harbour to the theatre depending on the size of your vehicle. Please therefore ensure that all details of the vehicles you tour are provided to us as soon as possible.
Sound Distribution boxes
space
Box No. Location
Detail
B2 Follow Spot Box T1 & 2; 1 x Comms; Q2.
B3 U/Circle S/L T3 & 4; 1 x Comms; S1 & 2.
B4 U/Circle S/R T5 & 6; 1 x Comms; S3 & 4
B5 Flys S/L T7 & 8; 1 x Comms; Q3; S5 & 6; AV1 & 2.
B6 Flys S/R T9 & 10; 1 x Comms; Q4; S7 & 8; AV1 & 2.
B7 Adv. Bar Roof Void T11 & 12; 1 x Comms; AV1 & 2; 1 x DMX; S9 - 14.
B8 D/Circle Front T13 & 14; 1 x Comms; AV1 & 2; Rel/Mic; 1 x DMX.
B9 D/Circle S/L Box T15 & 16; 1 x Comms; S16 & 16; 1 x DMX.
B10 D/Circle S/R Box T17 & 18; 1 x Comms; S17 & 18; 1 x DMX
B15 DSR T29 - 36; S19 & 20; 1 x Comms; Q6; AV1 & 2; 1 x
DMX; L1 - 8; Prompt desk; 3 x 13amp;
1 x 16amp.
B16 USR T37 - 40; 1 x Comms; Q7; S21 & 22; AV! & 2.
B17 USL 41 - 44; 1 x Comms; Q8; S23 & 24; AV1 & 2.
B18 DSL T45 - 52; S25 & 26; 1 x Comms; Q9; AV1 & 2; 1 x
DMX; 1 x Rigger; L1 - 8; Prompt desk; 3 x 13amp;
1 x 16amp.
B19 Pros Wall S/L S27 - 29.
B20