| General Information |
 |
|
 |
| Contact Numbers |
 |
| Theatre Director |
01534 511100 |
| Administration |
01534 511110 |
| Box Office |
01534 511115 01534 511114 |
| Technical Manager |
01534 511150 |
| Technical Office |
01534 511103 |
| Administration Fax |
01534 511199 |
| Email |
simon@jerseyoperahouse.co.uk |
|
|
 |
| Stage and Events Team |
 |
| The Stage and Events Team comprises of 3 full time members of staff and a team of casuals. The full time members of staff are: - |
| Technical Manager |
Simon Francklin |
| Deputy Technical Manager |
Chris Wink |
| Technician |
David Grierson |
|
|
 |
| Front of House Opening Times |
 |
| Lower Stalls Bar : Pre-show and intervals only |
| Circle Bar : 9am - 4pm (non performance days, excluding Sundays and Bank Holidays) 9am - 4pm, 6:30pm - 1am (performance days, excluding Sundays and Bank Holidays) 6:30pm - 1am (performance Sundays and performance Bank Holidays) |
| Box Office : 10am - 6pm (non performance days, excluding Sundays and Bank Holidays) 10am - 8:30pm (performance days, excluding Sundays and Bank Holidays)
6:30pm - 8:30pm (performance Sundays and performance Bank Holidays) |
| Hospitality Rooms : There are two hospitality rooms connected by a folding partition and both served by a single bar. This area is available by arrangement with the General Manager |
| The Stage |
 |
| A 1:25 ground plan of the Opera House is available on request. |
| General Stage Information |
 |
| Stage Height |
1300mm |
| Stage Rake |
None |
| Proscenium Width |
8450mm |
| Proscenium Height |
5500mm |
| Stage Depth |
8300mm to setting line 9100mm front of forestage |
| Stage extension (losing 48 seats) |
13100mm |
| Height to Grid |
14000mm |
| Scenery Flying Height |
12500mm |
| Height to Fly Floor |
5750mm |
| Flying width |
11000mm |
| Wing space |
| – Stage Left |
4700mm |
| – Stage Right |
3400mm |
| Loading access doors |
4500mm by 2200mm |
| Dock |
5000mm by 3000mm to stage |
|
|
 |
| General Stage Equipment |
 |
| The Venue has a selection of: - |
 |
| Stage braces/French braces of varying sizes |
| 20 Stage Weights |
| Various lengths of conduit |
| 4 x 5500mm hard black masking legs |
| 6 x 5000mm hard black masking legs |
|
|
 |
| Rostra |
 |
| 4 x 8’ x 4’ steel deck tops |
| 2 x 2000mm x 1000mm steel deck tops |
| Various sized legs (please check in advance). |
|
|
 |
| Flying |
 |
| Counterweight Flying |
33 Sets |
| Weight Capacity Per Cradle |
400Kg (873lb) |
Flying Bar Lengths (steel ‘H’ bar construction) |
11000mm |
|
|
| |
| Masking |
 |
| The venue has: - |
 |
| One set of black masking, comprising of: - |
 |
| 2 x set of full black tabs 18 ft high |
| 4 x Black borders |
| 8 x 3 metre wide black legs |
| 1 x Black Gauze |
| 1 x White Gauze |
| 1 x White Cyc |
| 1 x Set of Dark Blue with gold trimming house tabs. |
|
|
 |
| The venue also has three tab tracks. (2 rope pull and 1 manual swipe) |
| The Jersey Opera House is a traditional Edwardian horseshoe style auditorium with a curved proscenium arch and seating 620 people on three levels; Stalls, Dress Circle and Upper Circle. |
| Public access is via the Box Office entrance in Gloucester Street while stage door and Scene Dock door are situated in Seaton Place. |
| SAFETY CURTAIN MUST BE PRESENTED TO THE AUDIENCE FOR EACH PERFORMANCE |
| Flying System |
| All Bars are Single Purchase Counterweight |
 |
| |
Stage front
|
House tabs |
| Edge of stage |
0m |
- |
| Safety Curtain |
800mm |
- |
| 1(Permanent house tabs) |
1450mm |
0mm |
| 2 |
1800mm |
350mm |
| 3 |
2000mm |
550mm |
| 4 |
2200mm |
750mm |
| 5 |
2400mm |
950mm |
| 6 |
2600mm |
1150mm |
| 7 |
2800mm |
1350mm |
| 8 |
3000mm |
1550mm |
| 9 |
3200mm |
1750mm |
| 10 |
3400mm |
1950mm |
| 11 |
3600mm |
2150mm |
| 12 |
|
|
| 13 |
|
|
| 14 |
4200mm |
2750mm |
| 15 |
4400mm |
2950mm |
| 16 |
4600mm |
3150mm |
| 17 |
4800mm |
3350mm |
| 18 |
5000mm |
3550mm |
| 19 |
5200mm |
3750mm |
| 20 |
5400mm |
3950mm |
| 21 |
5600mm |
4150mm |
| 22 |
5800mm |
4350mm |
| 23 |
6000mm |
4550mm |
| 24 |
6200mm |
4750mm |
| 25 |
6400mm |
4950mm |
| 26 |
6600mm |
5150mm |
| 27 |
6800mm |
5350mm |
| 28 |
7000mm |
5550mm |
| 29 |
|
|
| 30 |
|
|
| 31 |
7600mm |
6150mm |
| 32 |
7800mm |
6350mm |
| 33 |
8000mm |
6550mm |
| 34 |
8200mm |
6750mm |
| 35 |
8400mm |
6950mm |
| 36 |
8600mm |
7150mm |
| 37 |
8800mm |
7350mm |
| Bars 12,13 29 & 30 are not installed |
|
|
 |
| Visiting Lighting Supply |
 |
The visiting lighting power is situated down stage Left.
The supply is 200 amps, 3 phase.
The distribution outlets are as follows: - |
| Type |
Phase |
Number |
| 200amp Power locks |
3 |
1 set |
|
|
 |
| Visiting Sound Supply |
 |
The visiting sound supply is a clean source and is situated under stage right. The distribution outlets are as follows: - |
| Type |
Phase |
Number |
| 32 amp Ceeform |
1 |
1 |
| 63amp Ceeform |
1 |
1 |
| 16amp Ceeform |
1 |
1 SL, 1SR |
| 13amp Standard |
1 |
2SL, 2SR |
|
|
 |
| There are at least 6 x 4way 13amp power outlets each side of stage at stage level. |
| Luminaries List |
 |
| Profiles |
| Type |
No. |
| Strand SL 15/33 (600w) |
18 |
| Strand SL 23/50 (600w) |
24 |
| Strand SL 10Degree fixed (600w) |
5 |
| ETC source 4 19degree (575w) |
2 |
|
|
 |
| 20 ETC Source 4 Zoom 15/30 are permanently rigged FOH, 14 Upper Circle Underhang, 6 Dome position. |
 |
| Fresnels |
| Type |
No. |
| Strand Quartet PC’s (650w) |
10 |
| Strand Quartet F’s (650w) |
20 |
| Strand Cantata PC’s (1200w) |
10 |
| Strand Cantata F’s (1200w) |
20 |
| Strand Alto (2500w) |
6 |
| Selecon Rama F’s (1200w) |
28 |
|
|
 |
| Floods and Par Cans |
| Type |
No. |
| ETC source 4 Par (750w) |
20 |
| Strand Coda floods (500w) |
12 |
| Strand iris3 cyc floods (1250w) |
4 |
| Parcans (1000w) |
24 |
|
|
| We have 20 of each lens type for the ETC pars (CP60, 61, 62, 95) |
| Follow Spots |
| 2 x Robert Juliat - Super korrigan F.S 1200 follow spots situated at the back of the upper circle in a ventilated room. |
| Hire Stock |
 |
| 8 x Martin Mac 250 |
| 18 x Chroma-Q scroller units and PSU/splitter box |
| 1 x 20” Mirror ball |
| 1 x Jem ZR24/7 Hazer |
| 2 x Data Smoke Factory |
| 1 x Jem Glaciator heavy smoke |
|
|
 |
| Please contact us for up to date charges |
 |
| Front of House Lighting Positions |
 |
| Circle front (fixed FOH position) |
12400mm |
| Upper circle |
13700mm |
| Auditorium Perches left and right |
15000mm |
| Boxes Left and Right |
5400mm |
| Dome position |
14200mm |
| Rear aud roof positions |
17500mm |
|
|
 |
| All positions done to stage front center line |
| On Stage Lighting Positions |
 |
The venue has four internally wired bars: -
2 x 18 ways
2 x 12 ways
The venue also has: -
4 x Ladders (fixed on runners 2 each side of stage)
6 x Boom Bases
|
| Also various lengths of scaffold for booms |
| PLEASE NOTE THAT DUE TO THE NATURE OF RESTORATION WORK NO ADDITIONAL RIGGING OF LIGHTING OR SOUND WILL BE ALLOWED IN THE AUDITORIUM |
| Control |
 |
| The Lighting control is provided by an MA Lighting Grand MA2 Light. |
| Backup provided by a Strand 520i and Strand 510i. |
| Dimming |
 |
| Strand LD90, 136 x 2.5k dimmers and 4 x 5k dimmers plus dimming for house lights, provides dimming
The dimmers all have hard-wired outlets and their locations are as follows. |
| Dimmers 1 to 6 |
Aud Left box |
| Dimmers 7 to 12 |
Aud right box |
| Dimmers 13 to 24 |
ADV bars |
| Dimmers 25 to 27 |
Dress circle bar |
| Dimmers 28 to 41 |
Upper circle bar |
| Dimmer 42 to 47 |
Aud Left Perch |
| Dimmer 48 to 50 |
Dome |
| Dimmer 51 to 56 |
Aud Right Perch |
| Dimmers 57 to 116 |
Stage overhead |
| Dimmers 117 to 128 |
Stage L & R ladders |
| Dimmers 129 to 132 |
Stage Right Floor |
| Dimmers 133 to 136 |
Stage Left Floor |
|
|
 |
| Communications |
 |
| The Opera has 12 Tech Pro Belt packs and head sets available.
There are various comms points around the venue in all the usual places.
|
| Cue Lights |
 |
| The Opera House has a 12-way Q light system, which is patchable to various points around the venue. |
| Video |
 |
| There are a number of video tie lines around the building, there is a camera FOH that feeds the patch bay. This system can be extended to anywhere in the building. |
| The Opera house has a Sanyo 2500 Lumen projector and a 14ft by 10ft screen (both front and rear projection surfaces). |
| These can be hired at a fee. |
| Sound Equipment |
 |
| PA System |
There are several sound distribution boxes around the auditorium and stage area, each has tie lines, speacon outlets, com's and cue light points, AV BNC points and some have DMX outlets.
Please see appendix 1 |
| PA Equipment |
 |
| Mixer |
Yamaha M7CL 48 channel digital desk |
| Mixer Other |
Soundcraft spirit folio 12 channel |
| Outboard Equipment |
Yamaha REV500 digital reverb unit
TC M3000 digital reverb/effect unit
2 x XTA GQ600 31 band graphics
2 x XTA DP224 loudspeaker controllers
4 x Behringer Composer Pro 2
4 x Behringer 3102 31 band graphics
Denon DNT620 CD/cassette player
2 x Sony MDS E11 Mini disc player |
| Amplifiers Main PA |
14 x D&B E-PAC dedicated amplifiers |
| Amplifiers (Monitors) |
1 x RCF 1200 2 channel |
|
|
 |
| PA Speakers F.O.H. |
 |
8 x D&B C690 Mid/High cabinets
2 x D&B E18 Sub cabinets
6 x D&B E3 loudspeakers
4 x Flying frames for D&B E3 |
| Monitor Speakers |
 |
| 2 x Community 15” driver wedges |
| Microphones |
 |
6 x Shure SM58
4 x Shure Beta 57A
7 X Shure SM57
2 x Audio Technica AT4053
1 x AKG D112
4 x AKG C418
4 x AKG C1000
2 x PCC160
1 x Audio Technica AT4033a/SC
1 x Shure SH55 (50’s period look)
6 x BSS AR133 DI boxes
2 x EMO DI boxes
8 x Short Boom Mic stands
14 x Tall Boom Mic stands
4 x Straight Mic Stands
Hire Stock
14 x Sennheiser Evolution 500 Series radio microphone receivers, with 12 Belt packs and 4 Hand held transmitters. |
| Visiting Mixer Position |
 |
Rear Stalls Requiring at least |
50mtrs of multicore |
|
|
 |
| Health and Safety at Work Act |
 |
| Would all incoming companies ensure that their employees or contractors work with in the Health and Safety at Work Act. |
| LOLER |
 |
| The Jersey Opera House is striving to meet the requirements of The Lifting Operations and Lifting Equipment Regulations 1998.
Would all incoming companies ensure that they have in their possession the correct documentation for any lifting equipment that is being brought in. Lifting equipment not having the correct documentation and test certificates will not be permitted to enter the building. |
| Portable Appliance Testing |
 |
Would all in coming companies ensure that all electrical equipment to be brought into the Opera house has been tested within the last twelve months, and ensure the equipment is marked and records are carried for inspection. Electrical equipment deemed to be in an unsafe condition would not be permitted to enter the building. But for a small fee we can PAT test all items. |
| Fire Regulations |
 |
The States of Jersey Fire Regulations require a Public Exemption Certificate for all performances, which use pyrotechnics, smoke machines and the smoking of cigarettes. If your performance contains such effects please contact the Technical manager as soon as possible. Applications received any later than three weeks before first performance will not be granted. All areas backstage are designated No Smoking Areas. |
| Please note: From 2007 Jersey will introduce non-smoking law in all enclosed work places. |
| Pyrotechnics |
 |
If you are bringing pyrotechnics into Jersey an Import Licence and Port d'arm certificate will be required. This also applies to fire arms unless they are soft metal blank-firers. These certificates need to be obtained in Jersey and we will therefore require full details of any such items you intend to bring. It is worth noting that there is a very good local supplier for most pyrotechnics. Applications received any later than three weeks before first performance will not be granted. |
| Vehicle Size (touring companies) |
 |
| We may need to organize a police escort from the harbour to the theatre depending on the size of your vehicle. Please therefore ensure that all details of the vehicles you tour are provided to us as soon as possible. |
| |
| |
 |